Biosystems One / Engineering verification example

MotionLab synthetic tracking validation note

Document version: 1.0   Date: August 7, 2026

Scope: This is an example engineering-verification report based on a deterministic synthetic fixture. It is not a human-subject study, clinical validation, protocol validation, or general accuracy claim.

Intended test

The fixture evaluates whether the two-dimensional point-tracking implementation can follow a known cyclic trajectory under controlled synthetic conditions while preserving frame-level provenance.

Method

Recorded result

FixtureCompletionRMS position errorInterpretation
Synthetic cyclic trajectory36 / 36 frames0.306 pxRegression result for this fixture only

Limitations

Synthetic performance does not establish accuracy on arbitrary cameras, codecs, subjects, tasks, marker conditions, occlusion patterns, or protocols. Large displacement, blur, rotation, scale change, deformation, and out-of-plane movement can require correction. AI-assisted landmarks remain estimates and require comparison with independently digitized recordings for protocol-specific research use.

Recommended external validation

For an intended protocol, use independently digitized real recordings and report RMS error, 95th-percentile error, lost-track rate, false-lock rate, and inter-rater variability.